EXTRACTED TEXT FROM: Instructions for Mini295,Mini230 Beam.docx


Instructions for use of LED stage lighting equipment








(Please read the instructions carefully and take good care of them before using the product.)
In order to use this product correctly and safely, please read the instructions carefully before installing and using this product. This manual contains important installation and application information. Please strictly follow the operation steps when installing and operating the product. Meanwhile, please take good care of this manual.
Our 230W beam lamp uses a new and beautiful high-temperature resistant metal body. This product is designed and produced in strict accordance with CE standard, and conforms to DMX512 signal protocol of international standard. It can be used independently or online. It has the characteristics of fast rotation, low noise and powerful function, and is suitable for small and medium-sized concerts, theaters, studios, nightclubs and bars.
Please dismantle the package carefully. After unpacking, check whether the product is damaged during transportation, and check whether the following contents are complete.

Beam lamp-1 set-1 manual.
Power line-1 signal line-1 signal line.
This product is in good condition before leaving the factory. In order to keep this product in good condition and ensure safe operation, users should follow the safety precautions and warnings in this manual.
Important: Damage caused by non-compliance with this manual is not covered by the warranty. The supplier is not responsible for the product problems caused by this.
If the product has been exposed to extreme unstable temperature environment (such as after transportation), please do not connect the power supply of the product immediately, because the water droplets caused by temperature changes may damage the product. Please use it after the product returns to normal temperature.
This product can be used in the voltage range of 90-240V, and it is an indoor product. Please make sure that the voltage used is not higher than the tolerable range of the product! ! The power plug must be plugged into a class I socket with good protection. The green or tawny conductor must be grounded.
Please check this product and the power cord frequently. Make sure that the power cord is not folded, damaged or scratched, and is not connected with other wires! Pay special attention when connecting the power cord or related wires. Be sure to unplug the power supply when not using this product or before cleaning.
Before using the product, please be familiar with the operation function of the product. Please don't let children or amateurs touch the product. Please do not shake this product. Don't use brute force when installing or operating the product. Don't let amateurs operate the product. Most of the damage is caused by unprofessional operation.
The product is not equipped with related maintenance accessories. Product maintenance and repair can only be carried out by professionals!
Please do not change this product without authorization, otherwise it may damage the product, and the damage caused by it is not covered by the warranty. Moreover, unprofessional operation may lead to short circuit, burn or electric shock, and so on.




Connection of DMX512 signal:
This lamp uses DMX512 signal control mode, and the control signals of lamps are connected in parallel. When connecting multiple lamps, it is best to use double-core shielded cable. When connecting, all lamps are connected through DMX signal jack (cannon seat) INPUT (input) and OUTPUT (output) on lamps, and the 3-core XLR plug terminals of signal wires connecting lamps must correspond to each other. When connecting lamp signals, It is recommended to use DMX signal terminator, which can avoid damaging the control signal due to electrical noise. The DMX signal terminator is a 120 ohm 1W resistor connected between pin 2 and pin 3 of an XLR plug and connected to the OUTPUT jack of the last lamp.
Calculation method of initial address code of lamps and lanterns:
The starting address code of the current lamp is equal to (the starting address code of the previous lamp)+(the number of channels of the lamp).
1: The initial address code value A001 of the first lamp.
2. The number of basic channels of the controller should be greater than or equal to the total number of channels used by lamps.
3. Note: When using any controller, each lamp must have its own starting address code. If the starting address code of the first lamp is set to A001, the number of lamps is 16CH; Then the starting address code of the second lamp is set to A017; The starting address code of the third lamp is set to A033; And so on, (this setting method also needs to be determined according to different consoles).

Product parameters:
Power supply: AC110-240V,50/60HZ light aperture: 128 mm.`
Optical opening angle: 2.1 degrees atomization: atomization+colorful.
Prism: two prism patterns: 13 patterns +1 white light
Color: 13 colors +1 white light size:
Product net weight:



Menu operation settings
primary menu
Submenu 1
Function setting
Brief introduction of function
DMX address

1-512

system setup
Display backward
normal
.


turn


Language settings
Chinese



English


Channel mode
20CH


operational mode
DMX



sound-controlled



automatic


Electronic lighting
close



open


Bulb default
On _ off


Bulb control
illumine


shortest route
On _ off


Horizontal reversal
close



open


Vertical inversion
close



open


XY speed
low speed



intermediate speed



fast


Optocoupler detection
close



open


Return to the superior
▲

information inquiry
Total time
0-9999


Bulb time
0-9999


binding hours
0-9999


display software
Vx001


XY software
Vx001


Small motor software
Vx001


Return to the superior
▲

Channel control
Color wheel rotation
0-255


stroboscopic
0-255


Dimming "
0-255


Fixed pattern
0-255


prism
0-255


Prism rotation
0-255


Fogging
0-255


Focus adjustment
0-255


Horizontal rotation
0-255


Horizontal fine adjustment
0-255


Vertical rotation
0-255


Vertical fine tuning
0-255


reset
0-255


light a lamp
0-255


XY speed
0-255


Color wheel speed
0-255


Focusing speed
0-255


Pattern speed
0-255


Return to the superior
0-255

functional mode
XY communication
normal
current state


mistake


Small motor communication
normal



mistake


Focusing hall
normal



mistake


Color wheel hall
normal



mistake


Pattern hall
normal



mistake


X-optical coupler
normal



mistake


Y optocoupler
normal



mistake


Fan speed
6500


Return to the superior
▲

appurtenance
Check code 1
0-9999


Total time
clear



carry out


Lamp time
clear



carry out


Restore default
default



recover



preserve


Horizontal rotation
0-255
Zero initial position

Vertical rotation
0-255


Focus adjustment
0-255


Prism 1
0-255


Prism 2
0-255


Prism rotation 1
0-255


Prism rotation 2
0-255


Fogging
0-255


Color combination
0-255


Fixed pattern
0-255


colour disc
0-255


Frequency flash
0-255


Stroboscopic midpoint
0-255


Ridge-1 midpoint
0-255


Mid-point of edge two
0-255


Atomization midpoint
0-255


Colorful midpoint
0-255


Return to the superior
▲

Advanced settings
Check code 2
0-9999


Signal encryption
open



close


DMX speed
0-255


DMX data packet
0-255


DMX type
0-055


DMX isolation
0-65535
The smaller the value, the more stable the signal is.

Driving plate temperature
< 110 degrees >
If it exceeds this range, red will be displayed.

Drive board 3.3V
3.0V - 3.6V
If it exceeds this range, red will be displayed.

Drive board 5.0V
4.5V - 5.5V
If it exceeds this range, red will be displayed.

Drive board 12V
10.0V - 14.0V
If it exceeds this range, red will be displayed.

Drive plate 36V
20.0V - 42.0V
If it exceeds this range, red will be displayed.

X state
be motionless



turn


X hall
normal



mistake
Show red

X-ray optical coupler phase
0-3


X optocoupler a
40-160
The standard setting of 100 exceeds the required range and displays red, but the red light on the panel does not give an alarm.

X optocoupler b
40-160
The standard setting of 100 exceeds the required range and displays red, but the red light on the panel does not give an alarm.

X optocoupler c
40-160
The standard setting of 100 exceeds the required range and displays red, but the red light on the panel does not give an alarm.

X optocoupler d
40-160
The standard setting of 100 exceeds the required range and displays red, but the red light on the panel does not give an alarm.

X current angle
000-540


X drive state
normal



mistake
Show red

Y state
be motionless



turn


Y optocoupler
normal



mistake
Show red

Y hall
normal



mistake
Show red

Y-coupler phase
0-3


Y optocoupler a
40-160
If it exceeds this range, red will be displayed.

Y optocoupler b
40-160
If it exceeds this range, red will be displayed.

Y optocoupler c
40-160
If it exceeds this range, red will be displayed.

Y optocoupler d
40-160
If it exceeds this range, red will be displayed.

Y current angle
000-250


Y drive state
normal



mistake
Show red

Return to the superior
▲

Channel level
Color wheel rotation
0-255
Current DMX channel value

stroboscopic
0-255


aiming
0-255


Fixed pattern
0-255


prism
0-255


Prism rotation
0-255


Fogging
0-255


Focus adjustment
0-255


Horizontal rotation
0-255


Horizontal fine adjustment
0-255


Vertical rotation
0-255


Vertical fine tuning
0-255


reset
0-255


light a lamp
0-288


XY speed
0-255


Color wheel speed
0-255


Focusing speed
0-255


Pattern speed
0-255


Return to the superior


reset
Reset all
cancel
manual reset


carry out


XY reset
cancel



carry out


Effect reset "
cancel



carry out


Return to the superior


Exit menu



16-channel table
CH1
colour
0--4
white light


5--9
White light+color 1


10--14
Color 1


15--19
Color 1+ Color 2


20--24
Color 2


25--29
Color 2+ color 3


30--34
Color 3


35--39
Color 3+ color 4


40--44
Color 4


45-49
Color 4+ color 5


50--54
Color 5


55--59
Color 5+ color 6


60--64
Color 6


65--69
Color 6+ color 7


70--74
Color 7


75--79
Color 7+ color 8


80--84
Color 8


85--89
Color 8+ color 9


90--94
Color 9


95--99
Color 9+color 10


100--104
Color 10


105--109
Color 10+color 11


110--114
Color 11


115--119
Color 11+color 12


120--124
Color 12


125--129
Color 12+color 13


130--135
white light


136--195
From fast to slow forward flow


196--255
Reverse flow from fast to slow
CH2
stroboscopic
0-5
Shutter closed


6--20
Turn on strobe


21-70
Synchronous strobe is slow to fast.


71-100
Random strobe is slow to fast.


101-150
Pulse strobe is slow to fast.


151-190
On-pulse strobe is slow to fast.


191-230
Turn off the pulse strobe slowly to quickly.


231-255
Shutter open
CH3
aiming
0-255
0-100% dimming
CH4
pattern
0--4
Baiguangkong


5--9
Pattern 1


10--14
Pattern 2


15--19
Pattern 3


20--24
Pattern 4


25--29
Pattern 5


30--34
Pattern 6


35--39
Pattern 7


40--44
Pattern 8


45-49
Pattern 9


50--54
Pattern 10


55--59
Pattern 11


60--64
Pattern 12


65--69
Pattern 13


70-125
From fast to slow counterclockwise running water


126-130
Stop running water


131-190
Running counterclockwise from slow to fast


191-195
Pattern 1 dithers from slow to fast.


196-200
Pattern 2 dithers from slow to fast.


201-205
Pattern 3 dithers from slow to fast.


206-210
Pattern 4 dithers from slow to fast.


211-215
Pattern 5 dithers from slow to fast.


216-220
Pattern 6 dithers from slow to fast.


221-225
Pattern 7 dithers from slow to fast.


226-230
Pattern 8 dithers from slow to fast.


231-235
Pattern 9 dithers from slow to fast.


236-240
The pattern 10 dithers from slow to fast.


241-245
The pattern 11 dithers from slow to fast.


246-250
The pattern 12 dithers from slow to fast.


251-255
The pattern 13 dithers from slow to fast.
CH5
prism
0-127
Remove the prism


128-255
Prism cut in
CH6
Prism rotation
0-127
0-400 degrees


128-189
Reverse flow from fast to slow


190-194
stop


195-255
From slow to fast forward flow
CH7
prism
0-127
Remove the prism


128-255
Prism cut in
CH8
Atomized colorful
0-127



128-169
Insertion atomization


170-255
Insert colorful
CH9
focus
0-255
From far to near
CH10
X axis
0-255
0-540 degrees
CH11
X-axis fine tuning
0-255
X-axis 16bit fine tuning channel
CH12
Y axis
0-255
0-240 degrees
CH13
Y axis fine tuning
0-255
Y-axis 16bit fine tuning channel
CH14
XY speed
0-255

CH15
NC
0-255
NC
CH16
Lighting reset
0-99
No function


100-105
Extinguish the bulb (5S)


106-199
No function


200-205
Turn on the light bulb (5S)


206-249
No function


250-255
All motors are reset (5S)

Lighting installation instructions:
This lamp can be placed horizontally, hung obliquely and upside down. Pay attention to the installation method when hanging obliquely and upside down. Fixed installation of the lamp: before positioning the lamp, ensure the stability of the installation site. When hanging upside down, make sure that the lamp does not fall off the support frame, and use safety ropes to pass through the support frame and lamp handle for auxiliary hanging. To ensure safety, prevent lamps from falling and sliding. When lamps are installed and debugged, pedestrians are forbidden to pass below. Regularly check whether the safety rope is worn and the hook screw is loose. If the lamps fall due to unstable hanging installation, the manufacturer will not bear any responsibility.


after-sales service
Attention! When the lamps leave the factory, they all undergo strict quality inspection, and the packaging is in good condition. Please operate according to the instruction manual. The machine failure caused by man-made reasons is not covered by the warranty.
The company provides technical advice to customers all his life.
If the product breaks down and needs to be repaired, please show the product warranty card and fill in the relevant contents truthfully. At the same time, we also hope that customers will feedback the problems of the product to us in time, so that we can improve the product at the first time.